Universal Hot Surface Ignition Integrated Furnace Control
Universal Hot Surface Ignition Integrated Furnace Control
Universal Hot Surface Ignition Integrated Furnace Control
Universal Hot Surface Ignition Integrated Furnace Control

Universal Hot Surface Ignition Integrated Furnace Control

Brand: JACKSON SUPPLY
UPC: 085267316149
SKU: S9200U1000

Regular price
$158.39
Sale price
$158.39

Description:
  • Main burner ignition using a 120V hot surface igniter.
  • Flame rectification circuit to monitor flame presence.
  • Monitoring of system pressure switch, high temperature limit, and rollout functions.
  • Appliance operation/safety requirements controlled via microprocessor.
  • Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM thermostat.
  • LED system status, performance and diagnostic indication.
  • Wire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances.
  • Twinning capability
  • EnviraCOM communication capability to enable local and/or remote system status, diagnostics, troubleshooting, and HVAC system control.
Specifications
  • Description: Universal single stage heating & cooling
  • Line Voltage: 120Vac (97-132 Vac)
  • Low Voltage: 24V (18-30Vac)
  • Frequency: 60 Hz
  • Operating Temperature (F): -40 F to +175 F
  • Operating Temperature (C): -40 C to +79 C
  • Operating Humidity Range (% RH): 0% to 95% non-condensing
  • Igniter Current: 1.0A resistive @ 95Vac output
  • Thermostat Anticipator Setting: (Stage 1 only) 100mA
  • PrePurge: 30 seconds
  • HSI Warmup Time: 17/27 or 30/30 seconds
  • Trial For Ignition: 4, 6, or 8 seconds
  • PostPurge: 15 seconds
  • Interpurge: 60 seconds
  • Ignition Trials: Three, two tries if flame is not sensed
  • Flame Failure Response Time: 2 Seconds max @ 1µA
  • Number of LEDs: 3
  • Heat On Fan Delay: 30 or 60 seconds
  • Heat Off Fan Delay: 60, 90, 120, or 180 Seconds
  • Cool Fan On Delay: 5 seconds
  • Cool Fan Off Delay: 0 or 60 seconds
  • Gas Control Used With: Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.
  • Cooling Contactor Used With: Any 24Vac contactor rated at 1.0A or less
  • Induced Draft Blower Load: 2.2FLA / 25LRA max @120Vac
  • Circulator Load: 14.5FLA / 25LRA max @120Vac
  • Type of Fan Used With: Standard Induction-Type Circulating Fan
Parameters:
Ignition Type:
Intermittent Hot Surface Pilot